V1FV SH
CPR B2ca-s1a, d2, a1
V1FV SH
CPR B2ca-s1a, d2, a1
- 3,2/3,2(3,6)kV
- SNCF CT 456
Descrizione
Descrizione
Norme
-
TestNF C32-070/C2
Application
These cables are used for signalling system.
Design
- Conductor: Stranded plain copper (class 2)
- Insulation: Cross-linked Polyethylene (XLPE)
- Assembling: An inner sheath acting as a filler with practically zero thickness
- Inner sheath: Low smoke, zero halogen (LSZH)
- Screen: semi-conductor and copper tape
- Bedding sheath: Low smoke, zero halogen (LSZH)
- Armour: Steel tapes
- Outer sheath: Low smoke, zero halogen (LSZH)
Marking
3.2 V1FV SH Nber of cores & cross-section C.T. 456 NEXANS 279 WW YY SNCF RESEAU B2ca-s1a, d2, a1 Manufacturing N° + metric marking
Core identification
3x: natural - black - red
Caratteristiche
Caratteristiche
Caratteristiche costruttive
Caratteristiche costruttive
Materiale del conduttore
Rame nudo
Tipo di conduttore
A trefoli, Classe 2
Isolamento
XLPE (polietilene reticolato)
Tipo di armatura
Due nastri in acciaio
Senza alogeno
IEC 60754-1
Caratteristiche dimensionali
Caratteristiche dimensionali
Numero di anime
-
Sezione del conduttore del cavo
- mm²
Diametro esterno max
- mm
Caratteristiche d'utilizzo
Caratteristiche d'utilizzo
Temperatura Operativa
-20 ... 60 °C
Fumo
IEC 60754-2
Densita' fumo
IEC 61034-2
Ritardante la fiamma
NFC 32070 C2
Temperatura massima di servizio del conduttore
90 °C